Single-unit air brakesQuestion 3 of 200
Correct67%2 of 3 answered
Incorrect33%1 of 3 answered

How can repeated brake applications activate the low-air warning even when no line has ruptured?

AThey can consume stored air faster than the compressor replenishes it.Correct answer
BThey increase reservoir size until the warning switch trips.Your answer
CThey convert compressed air into hydraulic fluid.
DThey automatically open every drain valve.
Incorrect.

Repeated applications can use reservoir air faster than the compressor can replace it, lowering pressure to the warning level. (Guide p. 157)